Specifications |
  |
 |
 |
 |
 |
| |
Sensor heads |
 |
| |
| IEC Class 1(FDA Class II) Type |
CD4-30 |
CD4-85 |
CD4-350 |
| High power Class 3R Type |
CD4-30-3R |
CD4-85-3R |
CD4-350-3R |
| Measuring Range |
30+/-5mm |
85+/-20mm |
350+/-100mm |
| Light Source |
(Regular Type) |
Class 2 (IEC/JIS) Class II (FDA) Red Laser Diode, 650nm, Max 1mW |
| |
(High Power Type) |
Class 3R (IEC/JIS) Class IIIa (FDA) Red Laser Diode, 650nm, Max 5mW |
| Spot Size (see Remark 1) |
30 × 100μm |
70 × 290μm |
300 × 700μm |
| Linearity (see Remark 2) |
±0.1%FS |
| Resolution (see Remark 3) |
1μm |
3μm |
40μm |
| Power Supply |
supplied by CD4A-N/P Controller |
| Temperature Drift |
±0.01% FS/ , F° |
| Laser Emission LED |
Green = Laser emission |
| Measurement LED |
Red = In range, 5% closer than center of measurement range (0 to 45%)
Orange = Within +/- 5% of the center of the measurement range
Green = In range, 5% farther than center of measurement range (55 to 100%)
Red/Green alternating = Out of measurement range |
| Environmental Rating |
IP67 |
| Operation Temperature / Humidity |
-10 to 45 (14 to 113F°), 35 to 85% RH |
| Storage Temperature / Humidity |
-20 to 60 (-4 to 140F°), 35 to 85% RH |
| Ambient illuminance |
Incandescent Lamp = Max. 3,000 lux |
| Vibration Resistance |
10 to 55 Hz double amplitude 1.5mm for XYZ |
| Shock Resistance |
50G (500m/s2) |
| Cable |
50cm (19.7 inch) cable |
| Cable Extension |
CD4CN-S-ROBOT (2m, 78 inch), CD4CN-5S-ROBOT (5m, 197 inch) |
| Material |
Aluminum die-cast |
|
 |
| |
| *1 |
Defined with center strength 1/e2 (13.5%). There may be leak light other than the spot size.
The sensor may be affected when there is a highly reflective object close to the detection area. |
| *2 |
256 times in average (using the special amplifier), object: White Ceramic. The value depends on objects. |
| *3 |
The typical value in the conditions of
256 times in average (using the special amplifier), object: White
Ceramic, distance range: Middle.
The value depends on objects. |
|
| |
| |
Sensor head (Specular Type) |
 |
| |
| Product Type |
CD4-L25 |
| Measuring Range |
25+/-1mm |
| Light Source |
Class 1 (IEC/JIS) Class II (FDA) Red Laser Diode, 650nm, Max 0.39mW |
| Spot Size (see Remark 1) |
25 × 35μm |
| Linearity (see Remark 2) |
±0.1%FS |
| Resolution (see Remark 3) |
0.1μm |
| Power Supply |
supplied by CD4A-LN/LP Controller |
| Temperature Drift |
±0.01% FS/ , F° |
| Laser Emission LED |
Green = Laser emission |
| Measurement LED |
Red = In range, 5% closer than center of measurement range (0 to 45%)
Orange = Within +/- 5% of the center of the measurement range
Green = In range, 5% farther than center of measurement range (55 to 100%)
Red/Green alternating = Out of measurement range |
| Environmental Rating |
IP67 |
| Operation Temperature / Humidity |
-10 to 45 (14 to 113F°), 35 to 85% RH |
| Storage Temperature / Humidity |
-20 to 60 (-4 to 140F°), 35 to 85% RH |
| Ambient illuminance |
Incandescent Lamp = Max. 3,000 lux |
| Vibration Resistance |
10 to 55 Hz double amplitude 1.5mm for XYZ |
| Shock Resistance |
50G (500m/s2) |
| Cable |
50cm (19.7 inch) cable |
| Cable Extension |
CD4CN-S-ROBOT (2m, 78 inch), CD4CN-5S-ROBOT (5m, 197 inch) |
| Material |
Aluminum die-cast |
|
 |
| |
| *1 |
Defined with center strength 1/e2 (13.5%). There may be leak light other than the spot size.
The sensor may be affected when there is a highly reflective object close to the detection area. |
| *2 |
256 times in average (using the special amplifier), object: White Ceramic. The value depends on objects. |
| *3 |
The typical value in the conditions of
256 times in average (using the special amplifier), object: White
Ceramic, distance range: Middle.
The value depends on objects. |
|
| |
| |
Amplifier Specification |
 |
| |
| Model |
CD4A-N, CD4A-LN (NPN output type) |
CD4A-P, CD4A-LP (PNP output type) |
| Number of connectable sensor heads |
Max. 2pcs |
| Sampling frequency |
100μs |
| Supply voltage |
12 to 24VDC ±10% |
| Power consumption |
270 mA/24V (When connected 2 sensor heads, with analog current output) |
| Temperature drift |
±0.01% FS/ |
| Analog output |
ANG(V) [A][B] |
Voltage output ±5V/FS (Output impedance 100 Ω, resolution 1mV) |
| ANG(mA) [A][B] |
Current output 4 to 20 mA/FS (Load impedance 300 Ω, resolution 1.5μA) |
| Alarm output |
ALM A, ALM B |
NPN open collector |
PNP open collector |
| Max. 100mA / DC24V (residual voltage Max. 1.8V) |
| Turn ON then the sensor head fails in measurement |
| Control output |
JDGE 1 to 5 |
NPN open collector |
PNP open collector |
| Max. 100mA / DC24V (residual voltage Max. 1.8V) |
| HI/LO setting and Hysteresis setting are available for each output. |
| Bank input |
BANK 0 to 2 |
ON when connected to GND |
ON when connected to 12 to 24V |
| 8 banks selectable |
| Hold input |
HOLD A, HOLD B, HOLD RST |
ON when connected to GND |
ON when connected to 12 to 24V |
| Laser off or measurement value holding (selectable in the menu) |
| Zero reset input |
ZERO A, ZERO B |
ON when connected to GND |
ON when connected to 12 to 24V |
| Zero reset of Head A measurement value / Head B measurement value / Calculation value is available |
| Optional features |
Averaging, Filter mode, Calculation, Holding, Alarming, Controlling output, |
| Analog output, Controlling sensitivity, Timer function, Memory function, Bank function, Zero reset |
| Display |
LCD display |
| Protection category |
IP20 |
| Operation temperature |
-10 to 45 (Non condensing) / For storage : -20 to 60 |
| Operating humidity |
35 to 85% RH / For storage : 35 to 85% RH |
| Vibration resistance |
10 to 55 Hz double amplitude 1.5mm, 2h for XYZ |
| Shock resistance |
20G (196m/s2) |
| Material |
Chassis: Polycarbonate, Connection terminals: Nylon 66 |
| Weight |
240g (including connection terminals) |
|
| |
 |
| |