CD1 Series, PSD system Laser type Displacement Sensor |
| Cable |
CD1-30N/P |
CD1-50N/P |
CD1-100N/P |
CD1-130N/P |
CD1-250N/P |
| M12 Connector |
CD1-30CN/CP |
CD1-50CN/CP |
CD1-100CN/CP |
CD1-130CN/CP |
CD1-250CN/CP |
| Transistor output |
N = NPN output, P = PNP output |
| Measuring range |
30+/-4mm |
50 +/- 10mm |
100 +/- 35mm |
130 +/- 50mm |
250 +/- 150mm |
| FS (full scale) |
8mm |
20mm |
70mm |
100mm |
300mm |
| Light source |
Class 2 Laser, 650nm, Max 3.3mW |
| Projected spot size |
0.1mm |
0.5mm |
0.5×1.2mm |
0.5×1.5mm |
0.8×1.2mm |
| Power supply |
12 - 24V DC (-5 to +10%) |
| Current consumption |
Max 120mA (DC12V), 75mA (DC24V), including analog output current |
| Resolution (typical value) |
(Unit : Micron. Under AUTO sensitivity. White ceramic as an object) |
 |
(Response Speed 100msec) |
1 |
3 |
15 |
20 |
150 |
| |
(Response Speed 10msec) |
3 |
10 |
50 |
70 |
500 |
| |
(Response Speed 1msec)
|
10 |
30 |
150 |
200 |
1500 |
| Linearity |
+/- 2% FS |
+/-1% FS |
+/- 2% FS |
+/- 3.5% FS |
+/- 5% FS |
| Temperature drift |
+/- 0.02% FS/ Celsius |
| Response speed |
100msec / 10msec / 1msec selectable |
| Sensitivity adjustment |
SET / FIX / AUTO |
| Analogue output |
4-20mA |
| Control output |
NPN or PNP, Max 100mA/DC30V, Residual Voltage Max 1.8V |
| Distance indicator |
Red
= Near, Orange = Middle, Green = Far, Red/Green = Error *Remark :
Errors as "out of measuring range", "Too high reflection", etc |
| Stability indicator |
Green = Stable, Red = Error, No light = Unstable, need adjustment |
| Output indicator |
Orange = Output |
| Teach-in indicator |
Green = Input, Red = Error |
| Blanking input |
NPN = Gray wire to 0V, PNP = Gray wire to +V |
| Delay function |
Off delay 40msec |
| Ambient illuminance |
Sun light : Max 10,000lux, Incandescent Lamp = Max 3,000lux |
| Operating temperature |
-10 to 40 degree C |
| Operating humidity |
35 to 95%RH |
Material
|
Zinc diecast |
| Protection / Noise regulation |
IP67 , CE |
| Warm-up period |
30minutes |